
1. The liquids are flammable! No flames
in lab!
2.
Study
glassware for cracks before beginning. If you find any, show the damaged
glassware to your instructor.
3.
Make
sure that the joints are flush in the distilling apparatus and that the vacuum
duct is unobstructed.
4.
Secure
H2O hoses with wire. Keep the water pressure moderate to low.
5. Do not discard distillate or pot
residue (exception: the spent cloves can go in the trash) in sinks, garbage
cans or general waste containers (large red cans in waste hood). Used
cyclohexane and toluene should be poured into the appropriately labeled
containers in the dispensing hoods. These liquids will be used again next year.
6.
Never
distill to dryness.
7.
Unless
instructed otherwise, heat conservatively.
8.
Build
your still several inches off the top of the bench.
9.
Do
not plug your powermite directly into a "normal" socket. It must be
plugged into a "powermite" (also called variac, step control).
10. Cyclohexane, toluene, and methylene
chloride are irritants and toxic. Methylene chloride is particularly irritating
when it is trapped under a ring or a glove. Avoid contact with these substances
by wearing gloves and goggles. Keep these compounds in the hood as much as
possible. In the event of a significant spill, consult your instructor. If you
suspect you have gotten any of these substances on your skin , flush the
exposed area with cold water for fifteen minutes. Occasionally, an organic
compound will seep through the nitrite gloves. Remember, gloves are just a
primary barrier. If you feel any itching or burning under your gloves, take the
gloves off and flush the exposed area for fifteen minutes with cold water.
|
Chemistry 211-212 |
Investigative
Experiments
|
||
|
Name |
TA Name: |
||
|
Experiment #
1 |
Lab Day: |
||
|
Unknown # |
|||
|
Section
1 (Pre-lab) |
(25 points) |
||
|
Section
2 (Results) |
(56 points) |
||
|
Section
3 (Post-lab questions) |
(70 points) |
||
|
Quality
of results |
(20 points) |
||
|
TOTAL |
(171 points) |
||
|
SCORE |
(percent) |
||
This
is your report cover. Please fill it out and attach it to your prelab
questions.
Eugenol Isolation
Flow Chart
Place Ground Cloves
in 100 mL Flask
with 40 mL of water

Steam Distill
Distillate
![]()
![]()
![]()


Distillation most commonly
refers to the process of vaporizing a liquid in one vessel and then
recondensing it in another vessel. It is usually used to separate one compound
from another (others), but it can also be used to help to identify a compound
because distillation is a reasonable way to determine the boiling point of a
liquid.
For a distillation to occur at a
reasonable rate, the compound in question must have a high vapor pressure. This
is the same as saying it should have a low boiling point or that it should be volatile
(N.B. volatile does not mean explosive). Vapor pressure refers to the rate at
which molecules escape from a liquid (solid). If there is a high rate of escape
or the vapor from the compound is exerting a lot of pressure against the
atmosphere, then the compound has a high vapor pressure. Compounds that have a
high vapor pressure at room temperature can often be detected by olfactory
analysis. Diethyl ether has a high vapor pressure as does naphthalene (moth
balls).
Boiling is not a necessary requirement for distillation, but it certainly accelerates the process. What is boiling? A liquid is boiling when the vapor pressure of the liquid equals that of the atmosphere giving the liquid the maximum rate of escape into the vapor phase. If a liquid has a low boiling point, its intermolecular forces are low and less energy is needed for molecules to escape into the vapor phase at their maximum rate. So if a liquid has a low boiling point, it has a higher vapor pressure at any temperature, but the maximum rate of escape can be achieved at a relatively low temperature. It is important to realize that like other phase changes, boiling is an equilibrium process. When a liquid is boiling the escaping tendency of the liquid into the gas phase equals that of the gas into the liquid phase.
As mentioned previously, boiling is
not a necessary requirement for distillation, but it is usually done to speed
up the collection of liquids in the receiver. The preceding discussion also
opens up the idea that there is a relationship between the atmospheric pressure
and the boiling point. That is, the more the atmosphere weighs down on the
liquid, the greater the energy input must be to have those molecules escape at
a high rate. On a high pressure day, our boiling points will go up and on a low
pressure day they will go down. Now you may be a little more interested in what
your weather person has to say each morning!
The relationship between atmospheric pressure and boiling point tells us that if we could reduce the atmospheric pressure in a controlled way, we could intentionally reduce the boiling point of a liquid. In principle, if the atmospheric pressure is lowered enough, liquids will boil at or below room temperature. In the laboratory, the atmospheric pressure is typically reduced by attaching a vacuum line to the distillation apparatus. In a couple of weeks you will use the rotary evaporators in the lab. These are really reduced pressure distillation apparatus. Reduced pressure distillation or vacuum distillation is useful when one wants to rapidly remove a volatile solvent from nonvolatile compounds, when minimal heating is important due to the thermal instability of a compound or when a compound has such a high boiling point that atmospheric distillation is not feasible.
First we will consider distillation as
a purification method. There are fundamentally two different types of
distillation that will be used routinely in this course, simple and fractional
distillation. The simple distillation apparatus is shown below. Simple
distillation is used in less critical separations of compounds. It can be used
to separate a non-volatile solid from a liquid. For example, if one had a
solution of sodium chloride in water, one could use this apparatus to distill
the water from the sodium chloride. Of course, the sodium chloride would remain
in the pot and the water would end up in the receiver. Simple distillation can
sometimes be used to separate two volatile liquids provided that the two
liquids have vastly different boiling points, say more than 50 degrees.
Simple distillation is a reasonable way to determine boiling point. One can load the pot with a pure unknown liquid and very carefully and slowly distill it. The still head temperature will quickly level off. The range of temperatures observed at the still head during the temperature plateau is the boiling range of the unknown. Since the boiling point is related to the structure of the compound, knowing the boiling point can be useful in identifying the compound.
The fractional distillation apparatus is
shown below. Obviously, the only difference in the set up is the insertion of a
column between the still pot and the still head. It doesn't look like much, but
that column can make the world of difference in a separation depending on its
construction and size. Fractional distillation can be used for very critical
separations. In principle, one could separate any two liquids provided there is
a difference in boiling point. Again though, the ability to separate is totally
dependent on the equipment and the way the distillation is carried out. To
understand this better this better some basic comprehension of distillation
theory is needed.

For a fractional distillation of two volatile liquids to be successful, it is imperative that the two liquids form a solution and that the solution behave in an ideal fashion, i.e., when the liquids vaporize, the vapor phase must be enriched in the more volatile component. It should make sense that if one component has a lower boiling point than the other it should have weaker forces and should have a higher vapor pressure. This being the case, the molecules should leave the solution at a higher overall rate thus producing an enrichment.
It is also important to realize that when heating (or even at room temperature) both types of molecules are vaporizing simultaneously, though hopefully one escapes in greater quantity than the other. This is one of the most common misconceptions about purification through distillation - that the more volatile component just jumps off the surface of the solution, leaving the less volatile component behind. This would be true of water in a solution of sodium, but not true at all of a solution of two reasonably volatile liquids.
The total
vapor pressure of a binary solution of two volatile components A and B can be
described as follows.
Pr XAP°A
+XBP°B
The above equation is a combination of
Raoult's law and Dalton's law of partial pressures. What it is basically saying
is that the total pressure of the system is the result of the partial pressure
of each of the components making up the solution. The partial pressures in turn
depend on the amount of each component and the vapor pressure of the individual
component. So if one had an equal quantity of diethyl ether (b.p. 34.6°C) and
hexane (b.p. 69°C), diethyl ether molecules would be escaping at a higher rate.
If one had unequal quantities of two compounds having the same vapor pressures,
then the one in larger quantity would be escaping at a higher rate.
To
understand enrichment or how purification occurs better let us first consider a
simple distillation. In theory, a simple distillation apparatus has one
theoretical plate. A theoretical plate is one enrichment. An enrichment is a
single vaporization resulting in an enhancement of the more volatile component
relative to the less volatile component. Suppose we have a 50:50 mixture of two
compounds A and B, respectively. Lets say that when this solution is initially
vaporized it is enriched to 60:40, A:B. If the simple distillation apparatus
truly has only one enrichment then the material collected in the receiver of
the distillation apparatus would be 60:40. If further enrichment is desired,
one could take the 60:40 material and add it to a clean still pot and
re-distill it. Upon re-vaporization it might go to 70:30, A:B and so on until
the desired purity is achieved. Obviously this is not a very efficient way to
go about a purification. Please note that I am making the enrichment increments
up in a convenient manner for the sake of simplicity. As you will see later,
enrichments do not occur in such even increments.
Switching to a fractional distillation set up will greatly improve matters. In the fractional distillation apparatus a column has been added. The column can vary quite a bit with regard to its structure. Generally, columns are better if they are longer and packed with a material that provides a large surface area. What does the column do? Well consider the hypothetical 50:50, A:B mixture again. This mixture is heated to boiling and it vaporizes. Lets assume it is enriched to 60:40, A:B as with the simple distillation. At this point, it is important to think about the boiling point of this solution. If you could take the thermometer from the still head and lower it into the distillation pot, you would find that the boiling point of the 50:50 mixture lies between the boiling point of the two individual compounds. What is the boiling point of the vaporized, enriched 60:40 material like? It should be closer to the boiling point of pure A which means the boiling point should be lower than that of the 50:50 mixture. Being lower boiling means that the enriched vapor phase condenses at a lower temperature. It rises up and hits a cooler part of the apparatus and condenses. It then starts to flow back into the pot. But being lower boiling means that it doesn't have to flow as low to revaporize. It is important at this point to realize that the column has a temperature gradient. The set up is hottest at the bottom and is cooler as one approaches the still head. So the 60:40 flows not quite as low and revaporizes again to say 70:30. The 70:30 has an even lower boiling point so it travels higher in the column before recondensing. It also does not have to drop as low to revaporize. Its boiling point is lower. The condensation/revaporization cycles continue over and over again until hopefully nearly pure material is obtained at the top of the column. This would be the material that is first condensed and collected in the receiver.
From the above discussion it is evident that a surface on which the liquid can condense is important. If the column were very short and/or not packed with a material to provide this surface, fewer condensation/ vaporization cycles would occur and the material initially condensed into the receiver would not be as pure. As mentioned previously another term for one of these enrichment cycles is a theoretical plate. The more efficient a column is the shorter the height equivalent of a theoretical plate (HETP). A very efficient column has many theoretical plates. You will discover through our investigations that our lab columns do not have many theoretical plates.
Once again it must be emphasized that
the increments of enrichment given above were quite ridiculous and were created
to make the explanation of enrichment a bit simpler to follow. The following vapor
phase composition diagram describes the quantitative aspects of enrichment
better. In reading this diagram realize that the X axis corresponds to the
percent composition of the solution. The Y axis corresponds to temperature in
degrees Celsius. There are actually two curves on the diagram. The upper,
convex curve corresponds to the vapor phase composition curve. The lower,
concave cure corresponds the liquid phase composition. The point "A"
given at the far left of the curve corresponds to the boiling point of pure A.
The point `B' given at the far right is the boiling point of pure B. Now how
does the curve work? Suppose You have a 50:50 solution of A:B. The 50:50, A:B is vaporized. If it is
an ideal solution, it will
become enriched in the vapor phase
with respect to A. To find out the vapor phase composition extend a line from
50:50 A:B on the X axis to the liquid phase composition curve. Then draw a
perpendicular until you intersect the vapor phase composition curve. Then draw
a perpendicular down to the percentages on the X axis. This ratio, 82:18, A:B
is the vapor phase composition. The process we just went through is the
equivalent of one enrichment, plate or simple distillation.
Now
to get the idea of what happens in a fractional distillation, this process
would be repeated over and over, one step for each plate in the column. So the
enriched, material would recondense and then revaporize. Upon revaporization it
would enrich to as indicated on the graph and so on. You will note that
enrichments get progressively smaller as one approaches pure "A".
This is significant for you in lab this week because if you start with an
unknown that is richer in cyclohexane your overall enrichment will be less that
someone who starts with a sample that is richer in toluene even though there
may be no variation in technique or equipment from you to your neighbor.
It
is important to recognize that other factors influence the purity of a sample.
Generally speaking, the faster a distillation is done, the cruder the material
will be at the top of the column. For a distillation to go faster, one normally
increases the rate of heating. With greater heat input, the column ends up
being hotter and has less of a temperature gradient. With a smaller temperature
gradient, fewer enrichments occur. To understand this better think about a
theoretical distillation occurring over a column having the exact same
temperature as the still pot. The material in the pot would vaporize and
enrich, but the column would be so hot that the material would not recondense
until it hit the condenser. Without multiple recondensations in the column,
little enrichment will occur. Even though a slower distillation is better, we
usually have to compromise a bit so that we can finish these labs in a reasonable
amount of time. So though your purity will not be its absolute best, stick to
the prescribed distillation rates so that you will not have to stay overnight
to finish the lab. We usually aim for a rate of one drop per second going into
the receiver. If your rate is less than that at any time during the procedure
increase the voltage. If it is more, decrease the voltage.
There are a few more terms you should
absorb at this point. The term holdup refers to the amount of liquid
that must be left in the distillation apparatus to avoid distilling to complete
dryness. We usually stop a distillation when the liquid level is just above the
boiling stones. Stopping at this point avoids the possible explosion of
peroxides that may have formed during vigorous heating. When this is done
liquid is left in the pot, but also on every surface in the still. Holdup is a
source of material loss in a distillation. The term throughput refers to
the rate at which one distills. The higher the throughput, the lower the
purity.
Boiling stones are normally small
chips of carbon (like charcoal). The
chips are porous and have many long, circuitous channels passing through their
structures. The channels have a large
total surface area. Trapped in these
channels are many smallgas molecules. One of the problems in heating a liquid
is that is may become superheated (heated above its boiling point, but unable
to boil because of the lack of nucleation sites). Superheated liquids have a tendency to
vaporize suddenly and violently, releasing a large amount of gas all at
once. The very large bubble or bubbles
of gas are released explosively pushing the hot liquid out of the container. This is called bumping. Why would this be a problem in distillation
(or in cooking – it can happen in a microwave!)? Not only do the long circuitous channels
provide surfaces for smaller bubbles to form (nucleation sites), but the gasses
already trapped in the channels are nucleation sites and facilitate the
movement of the high energy liquid molecules into the gas phase via these
pre-existing gasses. The evolution of
these small bubbles makes for even, safe boiling. Can boiling stones be reused?
To understand gas chromatography it is
helpful to review what you learned about paper chromatography or ion
chromatography. If you have not tried
paper chromatography, simply apply a dot of black marker to the bottom of a
paper towel strip. Dip the paper into
water and allow the water to rise by capillary action. You will see the “block ink” separate into is
constituent components. Gas Chromatography has many similarities to that
process. In paper chromatography there is a stationary and a mobile phase. The
components to be separated are applied to the bottom of the paper and the
separation relies on the differences in affinity of the compounds being
separated for the stationary phase and the mobile phase. The differences in
affinity can be related to the polarity of the molecules in most cases. In
paper chromatography, the stationary phase is the water that adheres to the
cellulose or the paper. The mobile phase was the solvent that rises up the
paper during the elution by capillary action. If a given component to be separated
has a higher affinity for the solvent (i.e., is more soluble) system it will
migrate higher. If a component has a relatively higher affinity for the
stationary phase it will
end up closer to the origin. Summing up, differences in
polarity translate into differences in affinity which result in a separation.
It is important to recognize that the separation is an equilibrium process. The
molecules being separated are continuously moving back and forth between the
two phases. The more soluble the molecules are in the mobile phase, the more
time they will spend there and the farther they will move. Please try to avoid
the natural inclination to believe that most soluble molecules leap off the
stationary phase into the mobile phase and fly up the paper, never returning to
the stationary phase and leaving the less soluble molecules behind. This ideal
situation would only happen in cases where the differences in solubility are
extreme.
Injection Port Column Detector Automatic Integrator
Gas chromatography involves the same elements
as paper chromatography. There is a stationary phase. In our GC's this is a
compound called carbowax that is packed inside the GC column. The mobile phase
is the helium gas which is continuously passing through the column. The greater
the affinity of a compound being separated for the mobile phase the faster it
will come off the column. Once again, successful separation is dependent on the
compounds being separated having different affinities for the phases. Please
refer to the following diagram of a GC for the ensuing discussion.
![]()
![]()
![]()
During your first week in lab, you
will discover that GC samples are applied to the column using a syringe. Now
what happens after you inject the sample? The injection port is very hot and
because of this, the sample is first vaporized. For your information, the
injection port is usually set at a temperature that is much higher than the
boiling point of the compounds being separated. The helium stream from the tank
is sweeping through this port and it picks up whatever has vaporized and
carries it into the GC column. The GC column is just a long stainless steel
tube that is usually coiled to fit in the oven. Remember, GC relies on
molecules spending some of their time in the gas phase so like the injection
port, the column is heated. The column temperature is set closer to the boiling
point of the compounds being separated. Often times, the temperature is a
little below the boiling points. Under these conditions, a substantial number
of the molecules to be separated are in the gas phase, but molecules are also
continuously condensing.
Let us use the GC separation of
cyclohexane (b.p. 80 0C) and toluene (b.p. 110 0C) as an
example. These components will be in the samples you will separate by GC during
the first two weeks of lab. When you inject a solution of cyclohexane and
toluene into the GC it is vaporized and swept into the column as described
above. In the cooler column, molecules condense and revaporize continuously.
Like paper chromatography, there is an equilibrium between the two phases. When
molecules enter the gas phase, they are swept up in the helium stream and make progress
along the column. When they condense
they stop moving. Considering the two compounds
involved in our separation, which is likely to spend more time in the vapor
phase? Cyclohexane
of course. Cyclohexane has a boiling point of 800C
where Toluene has a b.p. of 110°C. If the column temperature is set at
approximately 95 °C, more cyclohexane will reside in the
vapor phase at any given time than toluene. If the cyclohexane is spending more
time in the vapor phase it will move along more quickly than the toluene and
will eventually separate provided the column is long enough. This is the same
as saying that the cyclohexane will reach the end of the column first .
Enhancing the separation is the
presence of the stationary phase. Though there are a wide variety of stationary
phases one can use, in our GC's you will work almost exclusively with Carbowax.
Carbowax is a polar material that become a viscous oil upon heating. When
thinking about how the stationary phase might enhance the separation, one needs
to think about solubility. Which of the two compounds being used in our example
is more polar? Toluene is the correct answer. Its polarity is in part
responsible for its elevated boiling point. Being more polar (cyclohexane is
not polar) it should be more soluble in the polar stationary phase. This fact,
increases the likelihood that toluene will spend more time in the stationary
phase. The interaction with the stationary phase slows it down more with
respect to the cyclohexane, increasing the separation.
Upon reaching the end of the column,
the molecules enter the detector. There are several types of detectors one can obtain,
but our instruments all have thermal conductivity detectors. These detectors
measure any changes in the ability of the gas stream to conduct heat. When
changes occur, they are registered by the automatic integrators as a peak. When
anything other than helium passes through the detector, conductivity is altered
and a peak is observed.
Our instruments are hooked up to
computers that will show the peaks, the times of the peaks, and it will also
give you the percentage area of each peak read. This is useful information for
you because it gives you an indication of the purity of your sample. Realize
that you won't really know what the areas correspond to, i.e., do they
correspond to weight percent, volume percent or mole percent? Since the
detector responds differently to different compounds, you will not be able to
directly translate the numbers into any sort of units without calibrating the
instrument. Calibration requires more time than we normally have available in
lab. Regardless, the numbers are very useful in the sense that they will
provide you in a relative sense the purity of your sample.
The print out will also give you
numbers called retention times. The retention time is the time it takes for the
sample to go from the injection port to the detector. The shorter the retention
time, the lower its affinity was for the stationary phase. This usually means
that the compound had a low boiling point and a low polarity. The retention
time is analogous to the Rf values calculated in paper and thin layer chromatography.
In principle, it is a constant and can be used in conjunction with other
information to help identify a compound. As with Rf values in paper
chromatography, it is very difficult to duplicate retention times. For a
compound to give identical retention times on two different GC analyses, they
must be run under identical conditions, i.e., the temperatures, the column, and
the helium pressure must all be identical. It is very difficult to duplicate
conditions. You should not be shocked if your retention times do not match
those derived from a different machine with seemingly similar parameters. The
best way to begin to get a handle on the identity of a compound giving a peak
in a GC is to run standards. How would this be done in GC? To answer this think
about your paper chromatography experiment done in general chemistry.
A new technique that arises in this experiment is that of steam distillation. When you isolate the clove oil (eugenol and acetyl eugenol) from cloves, you will not have a solution. Instead, you will have two layers. Unlike the distillation of a solution (e.g., cyclohexane/toluene), these two layers will behave as distinct entities and there will be no dependence on how much of each species is present. The total pressure of the pot liquids can be defined by the following equation.
|
PT
= |
PA° |
+ |
PB° |
|
Total
vapor pressure |
Vapor
pressure pf pure “A” |
|
Vapor
pressure of pure “B” |
Notice there are no mole fraction terms in the equation.
This means that if you have lots of water or just a little it will make the
same contribution to the vapor pressure. What will happen when you distill? The
mixture will heat up and eventually boil. Please recall that boiling occurs
when the pot liquids have a vapor pressure equal to the external pressure. In
steam distillation, the pressures of the two components must add up to 760
torr. Throughout the heating process, water and clove oil molecules will
escape in proportion to their respective vapor pressures at the distilling
temperature. Since water has a significantly lower boiling point than eugenol
or acetyl eugenol, a much greater proportion of water molecules will be
vaporizing at any time during the distillation. Even though the components of
clove oil have low vapor pressures, they are volatile enough to vaporize to
some extent and a small amount will lift off with the water molecules. Since
the water and organic components are not interacting with each other, no
enrichment occurs and they will co-distill at a single temperature until all of
one component is completely distilled over. Normally, steam distillations are
carried out with a large excess of water. When all the organic component has been
distilled, pure water begins to distill. How is this situation reflected in the
appearance of the liquid and in the still head temperature?
While the steam distillation is occurring, the boiling point of the two together will be lower than the boiling point of the more volatile component. Why? At the end of the distillation, you will have two layers in the receiver which can be separated.
A helpful relationship when considering steam distillation in a theoretical sense is the ideal gas law, PV = nRT, where P = pressure, V = volume, n = moles, R = the gas constant and T = temperature. It is important to remember that all of these parameters refer to gaseous molecules. Since distillation involves the expansion of a liquid into a gas in a fixed volume (the still), the gas law can be useful in predicting the amount of water needed to complete a steam distillation or to figure out the proportion in which the organic and aqueous layers will co-distill. To gain a more practical expression, take the ratio of a gas law written for the gaseous water and one written for the organic gas. If this is done, one obtains the following expression.
(PH2O)
(VH2O) = (nH2O)R(TH2O)
![]()
![]()
(Porg) (Vorg) (norg)
R(Torg)
Fortunately, several
of the terms in the above expression cancel. The volumes cancel because both
gases occupy the same space, i.e., the still. The temperature terms cancel
because the two components are co-distilling at the same temperature. The R
terms obviously cancel.
The equation
therefore reduces to:
![]()
PH2O = nH2O
Porg norg
This simple equation sums up steam
distillation because it demonstrates that the amount of water obtained is
directly proportional to the vapor pressure of water at the distillation
temperature. The same is true of the organic component . Therefore, if the
organic component has a higher boiling point than the aqueous component, it
will contribute fewer molecules to the overall push against the atmosphere.
Nonetheless, the two components are working together. You can think of the
system as being like two people trying to push a broken down car. The weaker
person may not be contributing much, but is still reducing the work for the
stronger person. Because the organic is there, the water does not have to push
as hard against atmosphere and this is why the overall temperature is the below
the boiling point of pure water.
Now with all this sophisticated theory
stated, why is steam distillation useful? You might wonder why you would not
just take the cloves and press the oil out of them or extract the cloves
directly with an organic solvent such as methylene chloride or ether. The
problem with pressing the oil out (and this can be done) is that the yield is
very low. You might be able to imagine that much of the material would get
caught up in the solid matrix that constitutes most of the mass of the cloves.
The problem with a direct organic extraction is that many other nonvolatile
organic components of the clove would also dissolve in the solvent resulting in
a much more complex mixture. Purification would become time consuming and
material would lost with each added step. With steam distillation, only the
volatile components are collected and they can be isolated exhaustively if
enough water is used.
In summary, steam distillation is an ideal
way to separate volatile compounds from nonvolatile contaminants in high yield.
For these reasons it has been used extensively in the isolation of natural
products.
Odorants are small, volatile molecules
that constantly evaporate from their sources in low concentrations and are
perceived by chemical sensors (smell and taste receptors in our nose and
mouths). It date, approximately 1000 different types of molecular receptors
have been identified in the human nose allowing for humans to differentiate as
many as 10,000 different odorants. In mammals it is believed that there are
approximately 1000 genes responsible for olefaction. In humans, the number is considerably smaller,
approximately 374 3,4,5,6
Please read the following for a good summary
of the proposed mechanisms of olefaction
http://www.nationmaster.com/encyclopedia/Olfaction.
The following pages give the
structures and corresponding names of a number of scented compounds. You can
test the scents of most of these compounds while you are in this lab this week.
Though conservative scent testing of compounds is encouraged this week, the
general lab rule is to avoid organic fumes.
The most important concept to get out
of this reading and your experience in lab is that scent is related to
structure. Though we may not totally understand what it is about the structure
that causes us to perceive a particular scent or the exact biochemistry of the
sensation, we can say conclusively that the different scents of compounds are
due to specific aspects of their structure. In fact, all physical properties
are directly related to molecular structure. It is particularly noteworthy that
the tow carvones have such different scents!!!! These compounds are know as
enantiomers. They are very closely related, differing only in the spatial
arrangement of two groups. Specifically, they are mirror images of one another.
The fact that one carvone has a spearmint scent and the other has a caraway
scent indicates that smell receptors have a handedness or chirality2
associated with them and are able to chemically distinguish such subtly
different structures. This is really a profoundly important concept. When you
think of your body as a collection of a vast array of highly complex molecules
(yes, that is what you are), you start to wonder (at least I do) how each
molecule knows what it is supposed to do. The answer lies in molecular
recognition, i.e. molecules having very irregular shapes only being able to
interact with certain very complimentary molecules. This is what we mean by
handedness or chirality. This concept is probably one of the most significant
in biochemistry and the simple example of the carvones illustrates it rather
well.
Aromatic compounds received their name
because many compounds that contain aromatic rings (e.g. benzaldehyde from
almonds) have distinctive smells. However, it is now known that all compounds
with benzene rings have fragrance and not all fragrances have aromatic rings.
In this lab you will work with a series of structurally related compounds that
do contain aromatic rings and have unique fragrances.
You will be isolated clove oil in this
laboratory. Clove oil makes up 14-20% of the weight of cloves. It is
predominantly comprised of eugenol, but also contains a small amount of
acetyleugenol. Eugenol is also found in cinnamon leaf, West Indian bay and
allspice. Clove oil is easily isolated from cloves by steam distillation
because it is thermally stable at the distilling temperature and volatile
enough to contribute to the vapor pressure. As mentioned previously in this
lab, steam distillation is an excellent way to exhaustively isolate a volatile
organic from a solid matrix. In addition to its use as a fragrance and
flavoring, clove oil has medicinal applications. It has been used as a dental
analgesic for thousands of years.
Eugenol and acetyleugenol belong to a
class of compounds called vanilloids. Several of the vanilloids will be
available for you to test for scent. Vanillin (from vanilla beans), ethy
vanillin (artifical vanillin) and vanillyl alcohol (obtained from the chemical
reduction of vanillin) will also be available for comparison. The structures of
these compounds are given on the following page. In this lab, it is desired
that you will be able to determine the parts of the molecule that are
responsible for the quantity and quality of the scents you experience.
' The author recognizes the significant
contribution of Ms. Eliana Saxon to the writing of this section of the lab
manual. Eliana Saxon is a Bryn Mawr graduate who earned her doctorate in
chemistry at the University of California at Berley.
2Chiral: A molecule
or shape that is non super-imposable on its mirror image.
3AxeI, R., Scientific
American, Vol. 10, 1955, pp 130-137.
4Buck, L., Axel, R.,
Cell, Vol 65, 1991, pp175-187.
5http://www.nationmaster.com/encyclopedia/Olfaction
Vanilloids
and Esters
limonene R-(-)-carvone S-(+)-carvone

R-(+)-alpha-phellandrene citral
( a mixture of cis and trans)
Fractional
Distillation, Steam Distillation and Gas Chromatography
Before coming to
lab for the second week, please study all pages associated with this lab in
this book and complete the following pre-lab questions in your laboratory
notebook. If you feel shaky answering the questions, please feel free to
consult the lab texts on reserve in the library.
Prelab Questions
During this two
week lab you will separate an "unknown" solution of
toluene/cyclohexane by fractional distillation. What is unknown is the percent
composition of the solution. The composition of the unknown and the success of
your distillation will be determined using gas chromatography. You will also
isolate two natural products, eugenol and acetyl eugenol by steam distillation.
Obtain a 25-mL sample of an unknown solution
of cyclohexane and toluene from your TA/instructor. Analyze this mixture by gas
chromatography and then stopper the
solution and store it in your locker.
Note especially the
following:
a.
The flask heater is supported about 6
inches above the benchtop so that it can be lowered quickly in case of
emergency. The bottom of the 50-mL flask is in light contact with the heater
surface.
b.
Use a small amount of
stopcock grease on each joint as you assemble it. To grease joints, apply a
small amount of grease to the inner part of the joint before insertion. Move
the inner part around until the grease is spread. Grease is good, but remember,
it is not glue.
c.
A micro clamp is secured tightly
around the neck of the flask, while a micro clamp can be used to loosely
supporting the packed column. Support the West condenser with a micro clamp (or
if we have a shortage, a two large pronged clamp). Use yellow Keck clips as
additional support on round-bottom joint and the joint at the top of the column
. Generally, it is good to keep clamps relatively loose is kept loose to avoid
putting strain on the glassware and to allow for adjustments. DO NOT put a
clamp on the still head. Use only the three clamps shown. Clamps are for
support only, not to hold pieces together. The latter function is performed by
rubber bands (see below). Keck clips are
very fragile and should be used sparingly and gently.
d.
Two rubber bands hold
the pieces together. (Rubber bands are in plastic boxes on the ledges above
your bench) These should be attached immediately upon joining the two pieces
together. If you wait, the force of gravity will wind up costing money. Rubber bands are cheap and effective.
e.
The thermometer bulb
is just below the side arm of the still-head. It MUST be completely immersed in
the vapor during the distillation in order to obtain an accurate boiling point.
This is very important and frequently misunderstood. Do not use the mineral
spirit (blue) thermometers (they tend to run about five degrees low, unless
fully immersed). Use a mercury
thermometer (silver)
f.
The rubber tubing is
forced all the way onto the connection joints. The best way to accomplish this
is to wet the glass projections with water, then twist (rather than push) then
tubing on. If the tubing is not securely attached, there is a high chance of
its popping off at the least opportune time (namely when the water is running).
Unlike the picture above, the water inlet and outlet should face down.
g. The rubber tubing is further secured with copper wire and
pliers (also in plastic boxes on the ledges above your bench).
h.
The distillate is
collected in a 10-mL graduated cylinder, which may be supported with a mini
clamp so that there is very little gap between it and the outlet of the curved
adapter. This will minimize the escape of vapors. Do not support glassware on
books, with piles of towels, or in other imaginative, but unstable ways.
3. The purpose of boiling chips/stones
(which must be used when heating any liquid in the organic lab) is to provide a
large surface area on which bubbles can form to promote
smooth constant boiling. Otherwise most liquids will superheat (i.e. become hotter
than their boiling points) and then, at the slightest disturbance, will boil
over violently.It
is good to think of what would happen if the boiling stone were not present.
Most of the gas would form on the surface of the glass (at the interface with
the heater where things are hottest), the bubbles would tend to be very large.
The hot stone prevents the liquid from being superheated and the small bubbles
released from the many channels in the stone do not push the liquid up
violently.
4.
Remember that the
materials you are distilling are flammable. Be careful!
5.
HAVE THE TA OR LAB INSTRUCTOR CHECK
AND APPROVE YOUR APPARATUS BEFORE YOU START YOUR DISTILLATION. ARE YOU PLUGGED
INTO THE STEP CONTROL?
6.
Starting with a voltage control setting of
40-50 , begin distilling your unknown. Distill at a rate of ca. 0.5 drop/sec.
into the receiver (maintain a continuous rate of ca. 0.5 drop/sec. or you may
not finish the experiment) and collect the following fractions. Record the
still head temperature after every collection of 1 mL of distillate. You will
have to turn up the voltage constantly throughout this distillation. Whenever
you do not make progress for over five minutes, turn up the voltage by 5 volts.
Lack of progress is defined as follows.
d.
When
the liquid in the pot is not boiling.
e.
When
the condensate is not rising up the column.
f.
When
no distillate is coming over or when the distilling rate drops below 0.5 drop a
second.
Fraction A: Ambient
temperature to the end of the first "plateau" (ca. 88±5 °C). The
temperature will begin to rise faster than it had been rising. This fraction
should contain most of the cyclohexane.
Fraction B: Beginning
of the large temperature rise (ca. 88±5 °C) to the beginning of the second
"plateau" (ca. 108°C). This fraction should be small; it will contain
substantial amounts of cyclohexane and toluene.
Fraction C: ca. 107
or 108 °C to 111 °C. This fraction should contain most of the toluene. Collect
as much as you can, but DO NOT DISTILL TO DRYNESS.
Because
you have only one 10-mL graduated cylinder in your locker, proceed as follows.
Have three labelled (A, B, C) Erlenmeyer flasks (25 mL or 50 mL) with corksready
or alternatively, use clean vials labelled A, B and C. Begin your distillation
using your 10-mL graduated cylinder as the receiver for Fraction A. When you
decide to change to Fraction B, replace the graduated cylinder temporarily with
the "B" Erlenmeyer (or vial) , quickly pour the contents of the
graduated cylinder into the "A" Erlenmeyer (or vial), cork that flask
(or vial), and immediately resume collecting the distillate in the graduated
cylinder. Make an analogous maneuver involving the temporary use of the
"C" Erlenmeyer (or vial) as a receiver when you decide it is time to
change to Fraction C.
7. Remember
that the decision to change receivers should not be made on the basis of head
temperature alone, but rather on the changes and pattern of the change in head
temperature. Only when the temperature begins to rise significantly after the
first temperature "plateau" should you change receivers from Fraction
A to Fraction B. The exact temperature at which this change should be made will
depend on the composition of the mixture with which you start. For example, a
mixture that is richer in cyclohexane than toluene will start its first
temperature rise several degrees below 88 °C; similarly, a toluene-rich mixture
will start several degrees above 88 °C. The temperature at which the change
from Fraction B to Fraction C is made should not depend to any appreciable
extent on the original composition of the mixture. Why?
8. In any distillation you carry out, NEVER LET
THE POT GO DRY. When the volume in the distilling flask is about 1 mL (just
covering the boiling chips), lower the heater, turn off the heat, and allow the
system to cool. Small amounts of nonvolatile impurities including organic
peroxides may be present in any liquid. These will be concentrated by the
distillation of more volatile materials. The sharp rise in temperature that
occurs quickly upon complete removal of the solvent can sometimes result in a
serious explosion of such materials.
9. Analyze samples of Fractions A, B, and
C, and also the undistilled sample of your original mixture by gas
chromatography. Your instructor will teach you how to use the instrument. Note
that details regarding the conditions for this particular analysis and a sample
trace of a mixture of cyclohexane and toluene are posted on each instrument.
This information about conditions should be recorded on your own GC trace.
Under the conditions of the analysis, cyclohexane has a shorter retention time
than toluene.
If
there is a long line at the GC, save ca. 1 mL of each fraction in vials and
pour the balance of the liquid in the 50 mL round - bottom. Continue with the
simple distillation as described below. You can analyze your samples later or
on another day.
10. The
detelinination of the relative amounts of various compounds separated by gas
chromatography must begin with the measurement of the area under each peak. The
integrators automatically calculate the relative areas for you. You will find
these values on your GC trace.
1.
When you are finished with your
fractional distillation, combine all the fractions and the pot residue in the
50 mL round- bottom. Remove the packed distilling column and associated clamp.
Attach the filled round bottom to the still head. Raise the heater to meet the
round bottom. Please ask for help from your instructor if you are having
trouble making this transition. Begin heating with a voltage setting of 40-50.
2. Carry
out a simple distillation. Try to achieve a rate of distillation comparable to
your fractional distillation. You do not need to collect formal fractions, but
record distillate volume versus still head temperature as you did for the
fractional distillation (every 1 mL).
This
data will be useful when you are doing your write-up.
3. Distill
until you have ca. 1-2 mL left in the round bottom.
4. Pour
the collected distillate and pot residue into the designated waste bottle. THIS
EXPERIMENT IS NEARLY COMPLETELY RECYCLABLE. IF YOU DO NOT FOLLOW INSTRUCTIONS,
YOU WILL CAUSE UNNECESSARY WASTE AND POLLUTION.
Note:
%
yield = ((Mass of eugenol obtained) ÷ (mass of eugenol expected (theoretical)))
X 100
Distilling is beautiful. First of all, because it is a slow, philosophic, and silent occupation, which keeps you busy but gives you time to think of other things, somewhat like riding a bike. Then, because it involves a metamorphosis from liquid to vapor (invisible), and from this once again to liquid; but in this double journey, up and down, purity is attained, an ambiguous and fascinating condition, which starts with chemistry and goes very far. And finally, when you set about distilling, you acquire the consciousness of repeating a ritual consecrated by the centuries, almost a religious act, in which from imperfect material you obtain the essence.
Primo Levi, The Periodic Table
As
described in lecture, the first few lab reports will not be normal investigative
or preparative reports. We are going to take some time to work our way into
writing detailed, molecular level laboratory reports. Please only include what
is listed below.
1. Answer
all pre lab questions. (25 points)
2. A
report all raw and processed data
a.
fractional distillation
1. All
GC traces (12 points)
2. A
tabulation of all GC data (8 points)
3. A
plot of still head temperature vs. volume for the simple and fractional
distillations (10 points) This does not have to be done via computer.
b. steam distillation
1. Mass
of clove oil (eugenol and acetyl eugenol) or catnip’s essential oil obtained (4
points)
2. Percent
recovery of clove oil essential oil (6 points)
(note: % recovery = ((mass eugenol isolated) ÷ (mass of scope)) X 100)
3. Percent
yield of clove oil essential oil ( 6 points) (note_ described earlier)
4. Comparison
of the scent of clove oil essential oil to the others provided vanilloids (10
points)
3.
The answers to the following questions
a.
In your own words describe how a distilling
column works. (10 points)
b.
Now that you know the composition of
your unknown, estimate (very roughly, no calculation required) the boiling
point of the unseparated unknown. In terms of intermolecular forces, explain
your estimated boiling point. (6 points)
c.
Estimate the boiling point of a liquid
at 20 torr that boils at 230°C at 760 torr. For a rough estimate assume the
following. Each time the atmospheric pressure is halved, the boiling point
drops 10 °C. This is a very rough estimate. (4 points)
d.
Explain at a molecular or structural
level why cyclohexane has a lower GC retention time than toluene. (6 points)
e.
We did not complete the steam
distillation. How can you generally tell if a steam distillation is finished?
How much water would it have taken to exhaustively isolate all the clove oil in
your sample? (12 points)
f.
Examine the plots of the fractional
vs. simple distillation you prepared earlier in your write-up. Describe and
explain the differences. (12 points)
g.
Specifically describe where material
was lost in the eugenol procedure. (10 (points)
h.
List all errors that lead to less than
ideal results in your fractional distillation procedure. (10 points)
For your information, the following is the
definition of a successful fractional distillation:
a.
An A fraction that is enriched in
cyclohexane relative to the unknown.
b.
A B fraction that is similar in
composition to the unknown.
c.
A C fraction that is enriched in
toluene relative to the unknown.
d.
A small B fraction (6-10 mL).
e. A "long" plateau occurring over a relatively small temperature range for the A and/or C fractions.